Posted on: June 28, 2020 Posted by: admin Comments: 0

ASTM D1653 PDF

ASTM D and ASTM E96 both address the determination of the water vapor transmission and permeance of coatings. ASTM E96/E96M. ASTM D Standard Test Methods for Water Vapor Transmission of Organic Coating Films. Buy ASTM D R TEST METHODS FOR WATER VAPOR TRANSMISSION OF ORGANIC COATING FILMS from SAI Global.

Author: Meztikree Vilar
Country: Portugal
Language: English (Spanish)
Genre: Science
Published (Last): 13 October 2014
Pages: 60
PDF File Size: 20.68 Mb
ePub File Size: 3.98 Mb
ISBN: 866-5-43472-497-8
Downloads: 18048
Price: Free* [*Free Regsitration Required]
Uploader: Nimuro

The answer to the question posed is based on the substrate and the service environment. All paint and coatings are permeable to water, just to different degrees. Otherwise blistering and peeling will likely occur. These three terms are used to describe how quickly water vapor diffuses through a solid material.

The Water Vapor Permeance is often simply call the permeance, and the water vapor permeability is d11653 simply called the permeability.

The Water Vapor Transmission WVTpermeance, and permeability are very closely related in that one is calculated from the other. First the WVT is determined. Then the xstm is calculated by dividing the WVT by the vapor pressure across the material under test. The permeability is calculated by multiplying the permeance by the thickness of the material.

Water vapor is the gaseous phase of water. In the gas phase, water molecules move very rapidly and are not bound together. Water vapor can be produced by the evaporation of water or the sublimation of ice or snow.

It can also be produced by the boiling of water, but the steam that you can see coming out of your kettle technically is not water vapor. Water in the gas phase is invisible.

The Significance of the Permeability of Paints

The steam that you see consists of very small droplets of liquid water suspended in air. The fundamentals of the measurement of water vapor transmission in the laboratory are simple. WVT is s1653 by sealing a free qstm of the test material to the top of a container that is filled with water left or desiccant right. If the container is filled with water, the method is called the wet cup method or the water method.

  74LS74N DATASHEET PDF

The Significance of the Permeability of Paints | KTA UniversityKTA University

If the container is filled with desiccant, the method is called the dry cup method or the desiccant method. Essentially, the test determines how much vapor is lost through the film in the wet cup method or how much vapor the desiccant attracts or draws through the film for the dry cup method.

The weight data is plotted versus time. The system may at first gain or lose weight more quickly, and then settle into a constant or steady-state rate of weight change after a couple of days, or longer, depending on the type of material being tested.

If the cup is filled with water, the dish loses water over the course of the test so the plot points downward. If the cup contains desiccant, the dish gains water weight over the course of the test, so the plot points upward.

In either case, the slope of the plot is the rate of weight change and its units are mass per time.

ASTM D – 03 Standard Test Methods for Water Vapor Transmission of Organic Coating Films

For example, the units might be grams per hour or nanograms per 24 hours. What are the formulas and units for WVT, permeance, and permeability?

The WVT is determined by dividing the rate of weight change, which is the slope of the plot, by the area of the s1653 specimen. The permeance and permeability may be calculated from the WVT.

The scopes of the standards differ considerably. ASTM D covers the evaluations of films of coatings: The films may be free films or they may be applied to porous substrates. ASTM E96 covers many materials, including coatings. It can be used to test paper, plastic films, other sheet materials, fiberboards, gypsum and plaster products, wood products, and plastics. This correction can greatly change the results.

  IL TALISMANO DELLA FELICITA PDF

ASTM D does not discuss this correction. See the d163 below for more information about the correction. What does the magnitude of the permeance indicate? Materials can be classified by the magnitude of their permeance as follows.

How precise is the testing? If a sample is tested twice by the dry cup method, and asttm test consists of three replicate trials, the difference between the permeance results from the two tests are expected to be less than a quarter of a perm if the permeance is less than 1 perm.

For the wet cup method, two results, each the mean of triplicate aetm, are expected to differ by less than The repeatability values reported by these two ASTM standards indicate the permeance values determined are ball park figures.

What should one consider when comparing the permeance of coatings? Finally, be cautious when comparing the results obtained by the dry cup method to the wet cup methods. The wet cup method can produce higher results than the dry cup method when the same coating is tested under the same air temperature and humidity conditions. Your email address will not be published.

Leave this field empty. Inspection Instruments Pipeline Coatings — Volume 2: What is water vapor?

Verify that the units are the same Method: Temperature and Relative Humidity Testing Standard: Leave a Reply Cancel reply Your email address will not be published. We use cookies to understand how you use our site and to improve your experience.

This includes personalizing content and advertising. By continuing to use our site, you accept our use of cookies To learn more, click Read More to view our Privacy and Cookies X1653.